SYMBOL:
 |
DESCRIPTION
A screw-in, cartridge-style, pilot-operated, hydraulic check valve for use in blocking or load-holding circuits.
OPERATION
The PC10-32 allows flow from 2 to 3, while normally blocking flow from 3 to 2. Flow will be allowed from 3 to 2 when pressure is applied at 1.
The cartridge has a 2:1 pilot ratio, meaning that at least one-half of the load pressure held at 3 is required at 1 to open the valve.
The check is spring-biased to assure holding in static or no-load conditions.
A sealed pilot piston option is available.
FEATURES
• Hardened seat for long life and low leakage.
• Optional sealed piston.
• Industry common cavity.
RATINGS
Operating Pressure: 240 bar (3500 psi)
Flow: up to 30.2 lpm (8 gpm)
Maximum Internal Leakage at 240 bar (3500 psi):
3 to 2: 0.25 cc/minute (5 drops/minute)
2 to 1 without sealed piston: 115 cc/minute (7 cu. in./minute)
Pilot Ratio: 2:1
Check Spring Bias: 2.07 bar (30 psi); with sealed piston option: 6.9 bar (100 psi) minimum
Temperature: -40° to 100°C (-40° to 212°F) with Buna seals;
-26° to 204°C (-15° to 400°F) with Fluorocarbon seals.
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-3; See page 9.110.1_3w
Cavity Tool: CT10-3xx; See page 8.600.1
Seal Kit: SK10-3x-TM; See page 8.650.1 |