SYMBOL:
 |
DESCRIPTION
An in-line housed, pilot-operated, hydraulic check valve for use in blocking or load-holding circuits.
OPERATION
The PCV16 allows flow from B to A, while normally blocking flow from A to B. Flow will be allowed from A to B when pressure is applied at X.
This valve has a 3.8:1 pilot ratio, meaning that at least one-fourth of the load pressure held at A is required at X to open the valve.
The check is spring-biased at 1.7 bar (25 psi) to assure holding in static or no-load conditions.
A sealed pilot piston option is available.
FEATURES
• Hardened seat for long life and low leakage.
• Optional sealed pilot piston.
• Optional spring ranges.
• Check section is serviceable as a cartridge.
RATINGS
Operating Pressure: 240 bar (3500 psi)
Flow: up to 151 lpm (40 gpm)
Maximum Internal Leakage at 240 bar (3500 psi):
A to B: 0.25 cc/minute (5 drops/minute)
B to X without sealed piston: 245 cc/minute (15 cu. in./minute)
Pilot Ratio: 3.8:1
Check Spring Bias: 1.7 bar (25 psi)
Temperature: -40° to 100°C (-40° to 212°F) with Buna seals;
-26° to 204°C (-15° to 400°F) with Fluorocarbon seals.
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Seal Kit (for CV16-20): SK16-2x-T; See page 8.650.1
Piston Seal: See Dimension Drawing
Piston Seals:
O-Ring (1): Buna 6001119; Fluorocarbon 6003119
Back-ups (2): Buna 6010119; Fluorocarbon 6010119 |