SYMBOL:
 |
DESCRIPTION
A proportional solenoid-operated, 2-way, piloted, normally closed, , poppet-type, screw-in hydraulic cartridge valve for blocking or load-holding in high pressure applications requiring low internal leakage.
OPERATION
When de-energized, the HSP16-20 acts as a check valve, allowing flow from 1 to 2, while blocking flow from 2 to 1. When energized, the cartridge’s poppet lifts to open the 2 to 1 flow path. Flow is proportional to current applied to the coil.
Note: If low voltage is expected on the machine, 12 or 24 volt systems will require the use of 10 volt or 20 volt coils respectively. See “SP Valves and Coil Operating Parameters,” page 2.002.1_pdf.
FEATURES
• Continuous-duty rated coil.
• Efficient wet-armature construction.
• Waterproof E-Coils rated up to IP69K.
• 1000-hour salt-spray rated solenoid tubes.
• All HyPerformance products are tested to NFPA specification T2.6.1.
• and are tested at a verification level of 90% and an assurance of 99%.
RATINGS
Operating Pressure: 350 bar (5075 psi); 10% Cycle Life: 420 bar (6090 psi)
Fatigue Rating: 2 million cycles at 420 bar (6090 psi)
Burst Pressure: 1380 bar (20,000 psi)
Flow: Up to 265 lpm (70 gpm); see performance curves
Dither/Pulse Frequency: 100 Hz to 400 Hz
Hysteresis: From 3.8 to 11.3 lpm (1 to 3 gpm) less than 7.6 lpm (2 gpm);
From 11.3 to 113.4 lpm (3 to 30 gpm: less than 15.1 lpm (4 gpm)
Maximum Control Current: 1.2 amps
Internal Leakage: 7 drops/minute max. at 345 bar (5000 psi) inlet
Temperature: -54° to 107°C (-65° to 225°F) with Urethane seals
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: HVC16-2; See page 9.116.1_2w
Cavity Tool: HCT16-2xx; See page 8.600.1
Seal Kit: SK16-2U-O; See page 8.650.1
Coil Nut: Part No. 4553800
RECOMMENDED ELECTRONIC CONTROLLERS
The EVDR Series controllers are recommended for use with most HydraForce proportional valves. These newer electronic controllers are versatile, reliable, and easily configured and customized for a wide range of applications. See the EVDR Product Selection Guide.
For other Electronic Controllers, see page 2.001.1_pdf
|