SYMBOL:

Attention Manifold Designers:
To obtain these high flow capabilities using proportional flow controls and compensators, optimized cavity drillings
are required.
Please consult factory.
|
DESCRIPTION
A pressure-compensated electrically-variable three-port flow regulator that is a priority bypass-type control. This combination valve uses a PV70-33x proportional cartridge and an EC12-40 compensator.
OPERATION
The PFR70-33x-J will bypass all flow when de-energized at the pressure compensator spring value. When energized, this proportional valve/compensator package will regulate flow out of port 2, regardless of system working pressure, with an increasing current applied to the solenoid.
Manual Override: To Engage: Turn clockwise approximately 1 turn to reach start point.
Continue another approximately 5 turns to full shift.
To Disengage: Turn counterclockwise approximately 6 turns until positive stop is found.
FEATURES
• Excellent linearity and hysteresis characteristics.
• Hardened spool and cage for long life.
• Optional control orifice sizes.
• Optional coil voltages and terminations.
• Efficient wet-armature construction.
• Cartridges are voltage-interchangeable.
• Unitized, molded coil design.
• Coil waterproofing standard.
• Screw-in manual override option.
RATINGS
Operating Pressure: 207 bar (3000 psi)
Pressure Rise: Pressure at 1 begins to rise higher than the compensating pressure differential when bypass flow exceeds 41.6 lpm (11 gpm)
Internal Leakage: 410 cc/min. (25 cu. in./min.) fully closed at 207 bar (3000 psi) out port 2
Electrical: 2 standard voltage ratings:
|
|
Threshold Current
|
Max. Control Current
|
| Coil Voltage |
A & B Range |
C Range |
A & B Range |
C Range |
|
12 VDC
|
300 ±70 mA
|
360 ±70 mA |
1500 ±200
mA
|
1400 ±200 mA |
| 24 VDC |
150 ±35 mA |
180 ±35 mA |
750 ±100 mA |
700 ±100 mA |
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1 |