Valves - Electro-proportional Controls - Pressure Controls - Proportional Pressure Reducing/Relieving - Direct Acting - Pressure Rising with Current - Drop-in

EHPR98-G35

PROPORTIONAL PRESSURE REDUCING / RELIEVING CARTRIDGE VALVE

Overview

Description

The EHPR98-G35 is a direct-acting, spool-type, proportional, pressure reducing relieving valve. It is a 3rd generation HydraForce drop-in, flange mounted cartridge type valve for use with mineral based or synthetic (with lubricating properties) hydraulic fluids. The coil is an integral part of the valve and is not serviceable the regulated pressure is proportional to the input electrical current in the pressure ranges shown.

Features

  • Economical drop-in style.
  • Mounting plate option.
  • Compact size.
  • Retrofit option for EHPR98-T35.
  • Quick response time.
  • Inlet screen and pressure options.
  • Top-mounted connector.
  • Low leakage.
Pressure Ratings
Pressure rating:
  • 103 bar (1500 psi) Port 2
  • 45 bar (650 psi) Port 1
  • 34.5 bar (500 psi) Port 3
Proof pressure:
  • 54 bar (780 psi) Port 3
  • 345 bar (5000 psi) Ports 1 and 2
Burst pressure:
  • 258 bar (3750 psi) All ports pressurized
Control pressure at maximum control current:
  • 20 bar (290 psi)
Flow Ratings
Flow rating:
  • 6 lpm (1.6 gpm)
Maximum internal leakage:
  • 45 ml/min (2.7 in³/min) EHPR98-G35 at 24 bar (350 psi)
  • 15 ml/min (1.0 in³/min) EHPR98-G35F at 24 bar (350 psi)
Hysteresis:
  • 4 % PWM
Other Ratings
Cycle life:
  • 10 million cycles
Environmental rating:
  • IP69K
Corrosion protection:
  • 960 hour salt spray per ASTM B117
Temperature Ratings
Operating fluid temperature:
  • -40 to 149 °C (-40 to 300 °F) With HNBR seals
  • -26 to 204 °C (-15 to 400 °F) With fluorocarbon seals
  • -54 to 107 °C (-65 to 225 °F) With polyurethane seals
Storage temperature:
  • -40 to 70 °C (-40 to 158 °F)
Ambient temperature:
  • -40 to 80 °C (-40 to 176 °F)
Fluids:
  • Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range:
  • 7.4 to 420 cSt
Unit weight:
  • 0.26 kg (0.57 lb)
Internal wetted surface area:
  • 90 cm² (14 in²)
Maximum control current:
  • 1.130 A Coil 10 V
  • 0.940 A Coil 12 V
  • 0.780 A Coil 14 V
  • 0.565 A Coil 20 V
  • 0.470 A Coil 24 V
  • 0.390 A Coil 28 V
Dither PWM frequency:
  • 120 Hz EHPR98-G35
  • 150 Hz EHPR98-G35F
Coil resistance:
  • 4.83 ohm Coil 10 V
  • 7.28 ohm Coil 12 V
  • 10.05 ohm Coil 14 V
  • 18.35 ohm Coil 20 V
  • 29.54 ohm Coil 24 V
  • 40.36 ohm Coil 28 V
Valve inductance:
  • 68 mH Coil 10 V
  • 104 mH Coil 12 V
  • 152 mH Coil 14 V
  • 284 mH Coil 20 V
  • 433 mH Coil 24 V
  • 645 mH Coil 28 V
EHPR98-G35_Perf1(2022-02-24) EHPR98-G35_Perf2(2022-02-24) EHPR98-G35_Perf3(2022-02-24) EHPR98-G35_Perf4(2022-02-24) EHPR98-G35_Perf5(2022-02-24)
EHPR98-G35_Dim(2022-02-24)
Cavity:
  • VC-G027 Standard configuration
Installation type:
  • Flange mounted
Orientation restriction:
  • None
Mounting screw torque:
  • 3 to 4 N-m (2.2 to 3.0 ft-lb) For standard VC-G027 Cavity
  • 1.2 to 1.5 N-m (0.9 to 1.1 ft-lb) For retrofit VC-T009 Cavity
Note:
  • For retro-fitting into older drop-in cavities and other mounting options, see "Mounting-options-for-G3-valves" technical reference
Mounting plate:
  • HF P/N 4595096 Use with standard VC-G027 cavity
  • HF P/N 4210226 Use with retrofit VC-T009 cavity
Mounting screw:
  • M5 x 0,8 x 12 mm long, HF P/N: 4002609 (sold separately) Use with standard VC-G027 cavity
  • M4 x 0.7 x 12 mm long, HF P/N: 4001015 (sold separately) Use with retrofit VC-T009 cavity
Seal kit:
  • SK-G027-X X=seal option
Ported test body:
  • HF P/N: 71611X0
EHPR98-G35_Order(2022-02-24)

Model Options

EHPR98-G35DG-H-J-KL-U
D Plunger Option
CODE
DESCRIPTION
BLANK
Standard
F
Fast responding
G Screen
CODE
DESCRIPTION
BLANK
NONE
S
100 Mesh Screen
H Line Body
CODE
DESCRIPTION
0
No Body
J Seal
CODE
DESCRIPTION
G
HNBR (Hydrogenated Nitrile Butadiene Rubber)
V
Fluorocarbon
P
Polyurethane
K Coil Voltage
CODE
DESCRIPTION
10
10 VDC
12
12 VDC
14
14 VDC
20
20 VDC
24
24 VDC
28
28 VDC
L Coil Termination
CODE
DESCRIPTION
EJ
E-Coil, AMP Jr.
ER
E-Coil, Deutsch
EY2A
E-Coil, Metri-Pack 150.2
U Mounting Plate
CODE
DESCRIPTION
BLANK
None
G
Standard Single Valve Plate
T
Retro-Fit Plate