SYMBOL: |
DESCRIPTION
A solenoid-operated, 2-way, normally open, poppet-type, internally piloted, screw-in hydraulic cartridge valve designed for low leakage in load-holding applications.
OPERATION
When de-energized, the SV10-29 allows flow in both directions. When energized, the valve's poppet closes, blocking flow in both directions.
FEATURES
• Continuous-duty rated coil.
• Hardened seat for long life and low leakage.
• Optional coil voltages and terminations.
• Cartridges are voltage interchangeable.
• Manual override option.
• Optional waterproof E-Coils rated up to IP69K.
• Industry common cavity.
RATINGS
Operating Pressure: 240 bar (3500 psi)
Proof Pressure: 345 bar (5000 psi)
Flow: Up to 75.7 lpm (20 gpm)
Internal Leakage: 0.25 cc/minute (5 drops/minute) max. at 207 bar (3000 psi)
Temperature: -40° to 100°C (-40° to 212°F) with Buna seals;
-26° to 204°C (-15° to 400°F) with Fluorocarbon seals
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
Response Time: First indication of change of state with 100% voltage supplied
at 80% of nominal flow rating: Energized: 40 msec. De-energized: 32 msec.
Initial Coil Current Draw at 20°C: Standard Coil: 1.67 amps at 12 VDC;
0.18 amps at 115 VAC (full wave rectified).
E-Coil: 1.7 amps at 12 VDC; 0.85 amps at 24 VDC
Minimum Pull-in Voltage: 85% of nominal at 240 bar (3500 psi)
Filtration: See page 9.010.1
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
Cavity: VC10-2; See page 9.110.1_2w
Cavity Tool: CT10-2xx See page 8.600.1
Seal Kit: SK10-2x-M; See page 8.650.1
Coil Nut: Part No. 7004420 |