Valves - Directional Controls - Check Valve

HCV16-20

CHECK VALVE

Overview

Description

The HCV16-20X is a screw-in, cartridge style, hydraulic check valve for use as a blocking or load-holding device for high pressure applications.

Operation

The check valve allows flow from port 1 to 2, while normally blocking flow in the opposite direction. The cartridge valve has a fully guided poppet which is spring biased closed until sufficient pressure is applied at port 1 to open to port 2.

Features

  • Hardened seat for long life and low leakage.
  • Optional bias springs for back-pressure application flexibility.
  • All HyPerformance products are tested to the rigorous standards of the NFPA specification T2.6.1
  • All HyPerformance valves are tested at a verification level of 90% and an assurance of 99%.
Pressure Ratings
Pressure rating:
  • 350 bar (5075 psi)
  • 420 bar (6090 psi) 10% cycle life
Proof pressure:
  • 690 bar (10000 psi)
Burst pressure:
  • 1380 bar (20000 psi)
Flow Ratings
Flow rating:
  • 151 lpm (40 gpm)
Maximum internal leakage:
  • 0.25 ml/min (5 drops/min) At 350 bar (5075 psi)
Other Ratings
Cycle life:
  • One million cycles
Temperature Ratings
Operating fluid temperature:
  • -40 to 100 °C (-40 to 212 °F) With buna N seals
  • -26 to 204 °C (-15 to 400 °F) With fluorocarbon seals
  • -54 to 107 °C (-65 to 225 °F) With urethane seals
Storage temperature:
  • -40 to 70 °C (-40 to 160 °F)
Ambient temperature:
  • -40 to 90 °C (-40 to 194 °F)
Fluids:
  • Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range:
  • 7.4 to 420 cSt
Maximum operating contamination level:
  • 18/16/13 per ISO 4406
Unit weight:
  • 0.34 kg (0.74 lb)
  • 0.46 kg (1.02 lb)
  • 0.60 kg (1.32 lb)
Internal wetted surface area:
  • 168 cm² (26.01 in²) Regular adaptor
  • 245 cm² (37.98 in²) Tall adaptor for 100 and 150 psi springs
  • 290 cm² (44.89 in²) Tall adaptor for 200 psi spring
HCV16-20_Perf_Chrt1(2022-02-24) HCV16-20_Perf_Chrt2(2022-02-24)
HCV16-20_Dim_Dwg(2022-02-24)
Cavity:
Cartridge installation torque:
  • 258 to 285 N-m (190 to 210 ft-lb) Steel/ductile iron cavity
  • 237 to 250 N-m (175 to 185 ft-lb) Aluminum cavity
Orientation restriction:
  • None
Seal kit:
  • SK16-2N-T Buna N
  • SK16-2V-T Fluorocarbon
  • SK16-2U-O Urethane
HCV16-20_Order(2022-02-24)

Model Options

HCV16-20-H-J-R
H Line Body
CODE
DESCRIPTION
0
No Body
J Seal
CODE
DESCRIPTION
N
Buna-N
V
Fluorocarbon
U
PPDI Urethane
R Spring
CODE
DESCRIPTION
5
5 psi Bias Spring
8
8 psi Bias Spring
15
15 psi Bias Spring
25
25 psi Bias Spring
45
45 psi Bias Spring
60
60 psi Bias Spring