Cartridge Valves - Directional Control Valves - Shuttle

SELC-08A

RE18319-81-01(2023-11-07)
Description

The single ball shuttle allows flow from the higher pressure of two work ports 1 and 2 to the A port, externally located in the hexagon of the cartridge.

1) Only external seals for 10 valves

General:
Max. operating pressure:
  • 350 bar (5000 psi)
Max. flow:
  • See performance graph
Max. internal leakage:
  • 15 drops/min.
Fluid temperature range:
  • -30 to 100 °C (-22 to 212 °F)
Installation torque:
  • 34 - 41 Nm (25 - 30 ft-lbs)
Weight:
  • 0.06 kg (0.13 lbs)
Common cavity:
  • CA-08A-2N (see data sheet 18325-70)
Lines bodies and standard assemblies:
  • Please refer to section “Hydraulic integrated circuit” or consult factory
Seal kit 1):
  • Code: RG08A2010530100
  • material no: R901101544
Fluids:
  • Mineral-based or synthetics with lubricating properties at viscosities of 5 to 800 mm²/s (cSt)
Recommended degree of fluid contamination:
  • Nominal value max. 10µm (NAS 8) / ISO 4406 19/17/14
Installation position:
  • No restrictions
Other Technical Data:
  • See data sheet 18350-50
RE18319-81-02(2023-11-07)
RE18319-81-order(2023-11-07)
RE18319-81-dim(2023-11-07)