Cartridge Valves - Flow Control Valves - Flow regulator

VRFE-12A

RE18321-30-01(2023-11-07)
Description

A constant flow rate, regardless of system pressures, is established from 1 to 2 while a minimum pressure differential of 14 bar (200 psi) exists between the two ports. Output flow can be varied from closed to the nominal maximum rating for the valve. Free flow is permitted from 2 to 1, regardless of valve adjustment, by when pressure overcomes the spring bias of the valve check function.

¹) Only external seals for 10 valves

General:
Pressure min. - max.:
  • 14 - 350 bar (200 - 5000 psi)
Flow range:
  • see “Regulated flow range” table
Fluid temperature range:
  • -30 to 100 °C (-22 to 212 °F)
Installation torque:
  • 81 - 95 Nm (60 - 70 ft-lbs)
Weight:
  • 0.3 kg (0.66 lbs)
Cavity:
  • CA-12A-2N (see data sheet 18325-70)
Lines bodies and standard assemblies:
  • Please refer to section “Hydraulic integrated circuit” or consult factory
Seal kit¹):
  • Code: RG12A2010520100
  • material no: R901111377
Fluids:
  • Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm²/s (cSt)
Recommended degree of fluid contamination:
  • Nominal value max. 10µm (NAS 8) / ISO 4406 19/17/14
Installation:
  • No restrictions
Other Technical Data:
  • See data sheet 18350-50
RE18321-30-02(2023-11-07)
RE18321-30-order(2023-11-07)
RE18321-30-dim(2023-11-07)