Cartridge Valves - Pressure Control Valves - Pressure Reducing and Relieving

VRPE-10A

RE18318-58-01(2023-11-24)
Description

When a minimum pilot pressure is applied to port PIL, flow passes from 2 to 1. When the pressure at 1 exceeds the pressure setting (defined by pilot pressure times pilot ratio), the valve acts to restrict flow at 2. This increases the pressure drop through the valve and maintains consistent pressure at 1. Additionally, if pressure at 1 rises above the pressure setting, flow is relieved to 3 until the setting is re-attained.

¹) 1 - 3 to 80% of pressure setting

²) Only external seals for 10 valves

General
Max. operating pressure:
  • 350 bar (5000 psi)
Max. pilot pressure:
  • 175 bar (2500 psi) for Z=02 and Z=03 250 bar (3600 psi) for Z=13
Max. flow:
  • 20 l/min (5 gpm)
Max. internal leakage¹):
  • 50 cm³/min. (3 cu.in./min.)
Fluid temperature range:
  • -30 to 100 °C (-22 to 212 °F)
Installation torque:
  • 41 - 47 Nm (30 - 35 ft-lbs)
Weight:
  • 0.28 kg (0.62 lbs)
Cavity:
  • CA-10A-3N (see data sheet 18325-70)
Lines bodies and standard assemblies:
  • Please refer to section “Hydraulic integrated circuit” or consult factory
Seal kit²):
  • Code: RG10A3010520100
  • material no: R901111369
Fluids:
  • Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm²/s (cSt)
Recommended degree of fluid contamination:
  • Nominal value max. 10μm (NAS 8) / ISO 4406 19/17/14
Installation position:
  • No restrictions
Other Technical Data:
  • See data sheet 18350-50
RE18318-58-02(2023-11-24)
RE18318-58-order(2023-11-24)
RE18318-58-dim(2023-11-24)