General
Max. flow:
  • up to 70 l/min (19 gpm)
Max. operating pressure for steel body:
  • 350 bar (5000 psi)
Max operating pressure for aluminium body:
  • 210 bar (3000 psi)
Fluid Temperature:
  • -30 to 90 (-22 to 194)
Fluids: Mineral-based or synthetics viscosities of 20 to 380 mm²/s (cSt) with lubricating properties at:
MTTFd:
  • 150 years see RE 18350-51
To order manifold only, see data sheet RE 18325-85:
Other technical data:
  • See data sheet 18350-50
General
Installation orientation:
  • Unrestricted
Fluid Temperature:
  • -30 to 90 (-22 to 194)
Hydraulic
Max. operating pressure:
  • 350 bar (5000 psi)
Flow range:
  • 2 - 70 l/min (0.53 - 18 gpm)
Max. internal leakage:
  • 20 drops/min.
Switching time:
  • Opening ≤ 50 ms
  • Closing ≤ 100 ms
Fluid temperature range:
  • -20 to 80 °C (-4 to 176 °F)
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 20 to 380 mm²/s (cSt):
Installation torque:
  • 54 -66 Nm (40 - 49 ft-lbs)
Recommended degree of fluid contamination:
  • Nominal value max. 10 µm (NAS 8) ISO 4406 19/17/14
MTTFd:
  • 150 years see RE 18350-51
Special cavity:
  • 017-E see data sheet 18325-75
Other technical data:
  • See data sheet 18350-50
Electrical
Type of voltage:
  • DC voltage
Coil type:
  • D36
Supply voltage:
  • See data sheet 18325-90
Label Needed:
  • See characteristic curve
Power consumption:
  • 20 W
Type of protection:
  • Note: Note: Coils must be ordered separately
  • See data sheet 18325-90
RE18332-15-04(2023-11-21)
RE18332-15-order(2023-11-21)