Manifolds and Plates - Line Mount - 2-ways with emergency screw
VEDT-CE-16-08A-NC

Cartridge schemes

Technical data
* see performance graph on page 3

General:
Max. flow:
- 15 l/min (4 gpm)*
Max. operating pressure for steel body:
- 250 bar (5000 psi)
Max operating pressure for aluminium body:
- 210 bar (3000 psi)
Fluid Temperature:
- -30 to 90 (-22 to 194)
Fluids: Mineral-based or synthetics with lubricating properties at
viscosities of 20 to 380 mm²/s (cSt):
MTTFd:
- 150 years see RE 18350-51
To order manifold only, see data sheet RE 18325-85:
Other technical data:
- See data sheet 18350-50
Cartridge technical data
General
Installation orientation:
- Unrestricted
Fluid Temperature:
- -30 to 90 (-22 to 194)
Hydraulic
Max. operating pressure:
- 250 bar (3625 psi)
Flow range:
- up to 15 l/min (4 gpm)
Max. internal leakage:
- 5 drops/min.
Fluid temperature range:
- -20 to 80 °C (-4 to 176 °F)
Fluids: Mineral-based or synthetics with lubricating properties at
viscosities of 20 to 380 mm²/s (cSt):
Installation torque:
- 34 - 41 Nm (25 - 30 ft-lbs)
Recommended degree of fluid contamination:
- Nominal value max. 10 µm (NAS 8) ISO 4406 19/17/14
MTTFd:
- 150 years see RE 18350-51
Cavity:
- CA-08A-2N see data sheet 18325-70
Other technical data:
- See data sheet 18350-50
Electrical
Type of voltage:
- DC voltage
Coil type:
- D36
Supply voltage:
- See data sheet 18325-90
Admitted voltage tolerance: see characteristic curves and table:
Power consumption:
- 20 W
Type of protection:
Note: Coils must be ordered separately
- See data sheet 18325-90
Characteristic curves

Ordering code