Cartridge Valves - Directional Control Valves - Check

VURN-10A

RE18318-97-01(2023-11-01)
Description

When pressure at 2 rises above the spring bias pressure, the poppet is pushed from its seat and flow is allowed from 2 to 1. The valve is closed (checked) from 1 to 2. Precision machining and hardening processes allow virtually leak-free performance in the checked condition.

¹) Only external seals for 10 valves

General:
Max. operating pressure:
  • 350 bar (5000 psi)
Max. flow:
  • 60 l/min (16 gpm)
Max. internal leakage:
  • 5 drops/min.
Fluid temperature range:
  • -30 to 100 °C (-22 to 212 °F)
Installation torque:
  • 41 - 47 Nm (30 - 35 ft-lbs)
Weight:
  • 0.12 kg (0.27 lbs)
MTTFD:
  • 150 years see RE 18350-51
Cavity:
  • CA-10A-2N (see data sheet 18325-70)
Lines bodies and standard assemblies:
  • Please refer to section “Hydraulic integrated circuit” or consult factory
Seal kit¹):
  • Code: RG10A2010520100
  • material no: R901111363
Fluids:
  • Mineral-based or synthetics with lubricating properties at viscosities of 5 to 800 mm²/s (cSt)
Recommended degree of fluid contamination:
  • Nominal value max. 10µm (NAS 8) / ISO 4406 19/17/14
Installation position:
  • No restrictions
Other Technical Data:
  • See data sheet 18350-50
RE18318-97-02(2023-11-01)
RE18318-97-order(2023-11-01)
RE18318-97-dim(2023-11-01)