Cartridge Valves - Pressure Control Valves - Pressure relief

VMR1.EFB

RE18319-16-01(2023-11-24)
Description

Flow is blocked from 1 to 2 until pressure increases to meet the selected valve setting, lifting the conical, pilot-stage poppet from its seat. This action exhausts oil above the main-stage poppet (low- leakage, seat type), allowing it to shift and provide relief flow through 2 to tank.

The anti-cavitation function makes up for lacking oil volumes caused, for example, by leakage when pressure valves respond or in the case of leading loads. If the pressure at main port 1 is lower than the one at main port 2, the spool will be lifted out of its seat. Hydraulic fluid flows from main port 2 to main port 1. The spring chamber is drained to tank at port 3 allowing a consistent relief setting independent of back-pressure at port 2.

¹) At 80% of pressure setting.

²) Torque value valid for installation in cast iron and steel manifolds. In case of different body materials, please consult factory.

General
Max. operating pressure port 1 (P):
  • 420 bar (6000 psi)
Max. pressure admitted port 2 (T):
  • 50 bar (725 psi)
Max counter pressure port 3 Y (added to the pressure adjustment at a ratio of 1:1):
  • 420 bar (6000 psi)
Max. flow:
  • 100 l/min (63 gpm)
Max. internal leakage¹):
  • 15 drops/min.
Fluid temperature range:
  • -20 to 120 °C (-4 to 248 °F) (Viton)
Installation torque²):
  • 90 Nm (66,4 ft-lbs)
Weight:
  • 0.26 kg (0.57 lbs)
Special cavity:
  • FB (see data sheet 18325-75)
Lines bodies and standard assemblies:
  • Please refer to section “Hydraulic integrated circuit” or consult factory
Seal kit (Viton):
  • Code: RG16R2040520100
  • material no: R931002593
Fluids:
  • Mineral-based or synthetics with lubricating properties at viscosities of 10 to 380 mm²/s (cSt)
Recommended degree of fluid contamination:
  • Nominal value max. 10µm (NAS 9) / ISO 4406 20/18/15
Installation position:
  • No restrictions
MTTFD:
  • 150 years see RE 18350-51
Other Technical Data:
  • See data sheet 18350-50
Without surface protection:
  • In case of need of surface protection, please consult factory.
RE18319-16-02(2023-11-24)
RE18319-16-order(2023-11-24)
RE18319-16-dim(2023-11-24)