Compact Directional Valves - Non-compensated and Post-compensated - Intermediate elements ED Series

TI-00

Description

The intermediate elements TI-00-__- are designed to be fitted between two directional valve elements. They are available with check valve in (P) line, or in (T) line , or in both (P) and (T) line.

With the check valve on (P) line, they are normally fitted to allow free flow from (P) to (P1) and prevent reverse flow from (P1) to (P).

With the check valve on (T) line, they are normally fitted to allow free flow from (T1) to (T), and to prevent reverse flow (T) to (T1).

General
Weight TI-00-PT-..:
  • 0.54 kg (1.19 lbs)
Weight TI-00-0P-..:
  • 0.52 kg (1.15 lbs)
Weight TI-00-0T-..:
  • 0.52 kg (1.15 lbs)
Fluid Temperature:
  • –20….+50 (-4….+122) (NBR seals)
Hydraulic
Maximum pressure:
  • 250 bar (3625 psi)
Maximum inlet flow:
  • 50 l/min (13.2 gpm)
Hydraulic fluid General properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:
  • Mineral oil based hydraulic fluids HL (DIN 51524 part 1). Mineral oil based hydraulic fluids HLP (DIN 51524 part 2). For use of environmentally acceptable fluids (vegetable or polyglycol base) please consult us.
Fluid Temperature:
  • –20….+80 °C (-4….+176 °F) (NBR)
Permissible degree of fluid contamination:
  • ISO 4572: βₓ≥75 X=12…15 ISO 4406: class 20/18/15 NAS 1638: class 9
Viscosity range:
  • 5….420 mm²/s

For applications with different specifications consult us

RE18301-25-01
RE18301-25-order
RE18301-25-sym
RE18301-25-dim
1
Flange specifications for coupling to ED intermediate elements.
2
For tie rod and tightening torque information see data sheet RE 18301-90.
3
Identification label.
4
Test point for pressure gauge connection (plugged).