Manifolds and Plates - Line Mount - 4-ways

VED-CS-16-08A-43


Cartridge schemes (K)

RE18331-59-03(2023-11-20)
General

To order manifold only, see data sheet RE 18325-85

Max. flow:
  • 15 l/min (4 gpm)
Max. operating pressure for steel body:
  • 280 bar (4060 psi)
Max operating pressure for aluminium body:
  • 210 bar (3000 psi)
Ambient temperature range:
  • -30 to 90 (-22 to 194)
Fluids:
  • Mineral-based or synthetics with lubricating properties at viscosities of 20 to 380 mm²/s (cSt)
MTTFD:
  • 150 years see RE 18350-51
Other technical data:
  • See data sheet 18350-50
RE18331-59-01(2023-11-20)

Solenoid operated valves, direct acting spool type 4-way 3-position

RE18331-59-04(2023-11-20)
General
Installation orientation:
  • Unrestricted
Fluid Temperature:
  • -30 to 90 (-22 to 194)
Hydraulic
Max. operating pressure:
  • up to 280 bar (4060 psi)
Flow range:
  • up to 15 l/min (4 gpm)
Max. internal leakage at 230 bar:
  • 40 cm3/min. (2.4 cu.in/min.)
Fluid temperature range:
  • -20 to 80 °C (-4 to 176 °F)
Fluids:
Installation torque:
  • 34 - 39 Nm (25 - 29 ft-lbs)
Recommended degree of fluid contamination:
  • Nominal value max. 10 µm (NAS 8) ISO 4406 19/17/14
MTTFD:
  • 150 years see RE 18350-51
Cavity:
  • CA-08A-4N see data sheet 18325-70
Other technical data:
  • See data sheet 18350-50
Electrical
Type of voltage:
  • DC voltage
Coil type:
  • D36
Supply voltage:
  • See data sheet 18325-90
Admitted voltage tolerance: -10%/+15% of nominal voltage at 60°C amb. T:
Power consumption:
  • 20 W
Type of protection:
  • Note: Note: Coils must be ordered separately
  • See data sheet 18325-90

Note: in case of need of performance limits at specific different working conditions, please consult factory.

RE18331-59-05(2023-11-20)
Minimum switching voltage for all versions and 100% ED
Amb. T
Voltage required
60°C
-10% of V nominal
90°C
V nominal
RE18331-59-order(2023-11-20)