Manifolds and Plates - Line Mount - 4-ways
VED-CS-16-08A-43

Technical data
Cartridge schemes (K)

General
To order manifold only, see data sheet RE 18325-85
Max. flow:
- 15 l/min (4 gpm)
Max. operating pressure for steel body:
- 280 bar (4060 psi)
Max operating pressure for aluminium body:
- 210 bar (3000 psi)
Ambient temperature range:
- -30 to 90 (-22 to 194)
Fluids:
- Mineral-based or synthetics with lubricating properties at viscosities of 20 to 380 mm²/s (cSt)
MTTFD:
- 150 years see RE 18350-51
Other technical data:
- See data sheet 18350-50
Dimensions

Solenoid operated valves, direct acting spool type 4-way 3-position

Cartridge technical data
General
Installation orientation:
- Unrestricted
Fluid Temperature:
- -30 to 90 (-22 to 194)
Hydraulic
Max. operating pressure:
- up to 280 bar (4060 psi)
Flow range:
- up to 15 l/min (4 gpm)
Max. internal leakage at 230 bar:
- 40 cm3/min. (2.4 cu.in/min.)
Fluid temperature range:
- -20 to 80 °C (-4 to 176 °F)
Fluids:
Installation torque:
- 34 - 39 Nm (25 - 29 ft-lbs)
Recommended degree of fluid contamination:
- Nominal value max. 10 µm (NAS 8) ISO 4406 19/17/14
MTTFD:
- 150 years see RE 18350-51
Cavity:
- CA-08A-4N see data sheet 18325-70
Other technical data:
- See data sheet 18350-50
Electrical
Type of voltage:
- DC voltage
Coil type:
- D36
Supply voltage:
- See data sheet 18325-90
Admitted voltage tolerance: -10%/+15% of nominal voltage at 60°C amb.
T:
Power consumption:
- 20 W
Type of protection:
Note: Coils must be ordered separately
- See data sheet 18325-90
Characteristic curves
Note: in case of need of performance limits at specific different working conditions, please consult factory.

Minimum switching voltage for all versions and 100% ED
Amb. T
Voltage required
60°C
-10% of V nominal
90°C
V nominal
Ordering code