Flow is normally allowed from 3 to 2. When pilot pressure at 1 rises above the combined pressure of the spring bias, plus pressure at 3, the valve shifts to block flow. The valve may be used in switching or compensation type applications, and will maintain a constant pressure drop across a fixed (or variable) orifice upstream of 3 when installed and piloted per the diagram above.

¹) Only external seals for 10 valves

General:
Max. operating pressure:
  • 350 bar (5000 psi)
Max. flow for Z=05:
  • 80 l/min. (21 gpm)
Max. flow for Z=11:
  • 120 l/min. (32 gpm)
Flow maintenance:
  • ± 20% (Z=05); ± 10% (Z=11)
Fluid temperature range:
  • -30 to 100 °C (-22 to 212 °F)
Installation torque:
  • 108 - 122 Nm (80 - 90 ft-lbs)
Weight:
  • 0.4 kg (0.88 lbs)
Cavity:
  • CA-16A-3N (see data sheet 18325-70)
Lines bodies and standard assemblies:
  • Please refer to section “Hydraulic integrated circuit” or consult factory
Seal kit¹):
  • Code: RG16A3010520100
  • material no: R930001177
Fluids:
  • Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm²/s (cSt)
Recommended degree of fluid contamination:
  • Nominal value max. 10µm (NAS 8) / ISO 4406 19/17/14
Installation:
  • No restrictions
Other Technical Data:
  • See data sheet 18350-50