Manifolds and Plates - Line Mount - 2-ways with emergency screw
VEI-CE-16-021-NC

Cartridge schemes (K)

Technical data

General:
Max. flow:
- up to 150 l/min (40 gpm)
Max. operating pressure for steel body:
- 350 bar (5000 psi)
Max operating pressure for aluminium body:
- 210 bar (3000 psi)
Fluid Temperature:
- -30 to 90 (-22 to 194)
Fluids: Mineral-based or synthetics with lubricating properties at
viscosities of 20 to 380 mm²/s (cSt):
MTTFd:
- 150 years see RE 18350-51
To order manifold only, see data sheet RE 18325-85:
Other technical data:
- See data sheet 18350-50
Cartridge technical data
General:
Installation orientation:
- Unrestricted
Fluid Temperature:
- -30 to 90 (-22 to 194)
Hydraulic:
Max. operating pressure:
- 350 bar (5000 psi)
Flow range:
- 5 - 150 l/min (1 - 40 gpm)
Max. internal leakage:
- 20 drops/min.
Switching time:
- Closing ≤ 100 ms
- Opening ≤ 50 ms
Fluid temperature range:
- -20 to 80 °C (-4 to 176 °F)
Fluids: Mineral-based or synthetics with lubricating properties at
viscosities of 20 to 380 mm²/s (cSt):
Installation torque:
- 130 - 150 Nm (96 - 111 ft-lbs)
Recommended degree of fluid contamination:
- Nominal value max. 10 µm (NAS 8) ISO 4406 19/17/14
MTTFd:
- 150 years see RE 18350-51
Special cavity:
- 021-E see data sheet 18325-75
Other technical data:
- See data sheet 18350-50
Electrical:
Type of voltage:
- DC voltage
Coil type:
- D36
Supply voltage:
- See data sheet 18325-90
Label Needed:
- See characteristic curve
Power consumption:
- 20 W
Type of protection:
Note: Coils must be ordered separately
- See data sheet 18325-90
Characteristic curves