Manifolds and Plates - Line Mount - 2-ways

VEI-CS-16-10A

RE18331-62-01
RE18331-62-02
General:
Max. flow:
  • up to 70 l/min (19 gpm)
Max. operating pressure for steel body:
  • 350 bar (5000 psi)
Max operating pressure for aluminium body:
  • 210 bar (3000 psi)
Fluid Temperature:
  • -30 to 90 (-22 to 194)
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 20 to 380 mm²/s (cSt):
MTTFd:
  • 150 years see RE 18350-51
To order manifold only, see data sheet RE 18325-85:
Other technical data:
  • See data sheet 18350-50
General
Installation orientation:
  • Unrestricted
Fluid Temperature:
  • -30 to 90 (-22 to 194)
Hydraulic
Max. operating pressure:
  • 350 bar (5000 psi)
Flow range:
  • 2 - 70 l/min (0.53 - 18 gpm)
Max. internal leakage:
  • 20 drops/min.
Switching time:
  • Opening ≤ 50 ms
  • Closing ≤ 100 ms
Fluid temperature range:
  • -20 to 80 °C (-4 to 176 °F)
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 20 to 380 mm2/s (cSt):
Installation torque:
  • 44 - 56 Nm (33 - 41 ft-lbs)
Recommended degree of fluid contamination:
  • Nominal value max. 10 µm (NAS 8) ISO 4406 19/17/14
MTTFd:
  • 150 years see RE 18350-51
Cavity:
  • CA-10A-2N see data sheet 18325-70
Other technical data:
  • See data sheet 18350-50
Electrical
Type of voltage:
  • DC voltage
Coil type:
  • D36
Supply voltage:
  • See data sheet 18325-90
Label Needed:
  • See characteristic curve
Power consumption:
  • 20 W
Type of protection:
  • Note: Note: Coils must be ordered separately
  • See data sheet 18325-90
 
Manual override options (X)
Seal and prot. cap. (Y)
 
A
B
C
D
E
F
0
K=all versions
K=06; K=32
K=06; K=32
K=03; K=05 K=31
K=03; K=05 K=31
K=03; K=05 K=31
V
K=all versions
K=06; K=32
K=06; K=32
K=03; K=05 K=31
K=03; K=05 K=31
K=03; K=05 K=31
P
/
K=06; K=32
K=06; K=32
K=03; K=05 K=31
/
/
T
/
K=06; K=32
K=06; K=32
K=03; K=05 K=31
/
/
RE18331-62-03

for solutions availability (K-X-Y combinations), please refer to TAB.1 on page 2.