Cartridge Valves - Electro-proportional Valves - 4-ways

VEPS-10A-43

For best results it is recommended to have at least 5 bar back pressure in the tank line (e.g. 5 bar check valve).

General:
Weight (with coils):
  • 0.85 kg (1.87 lbs)
Installation position:
  • Any
Fluid Temperature:
  • -40 to 110 (-40 to 230)
Salt spray test to DIN 50021:
  • 720 h
Hydraulic:
Max. operating pressure port 2, 3, 4:
  • 350 bar (5075 psi)
Max. operating pressure port 1:
  • 250 bar (3625 psi)
Max. flow:
  • 25 l/min. (7 gpm)
Max. internal leakage:
  • < 60 ml/min. (with Δp=250 bar; HLP46, Toil = 40°C)
Fluid temperature range:
  • -40 to 80 °C (-40 to 176 °F)
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 5 to 1000 mm²/s (preferably 10 to 100 mm²/s):
Recommended degree of fluid contamination:
  • Nominal value max. 10µm (NAS 8) ISO 4406 19/17/14
Cavity:
  • CA-10A-4N see 18325-70
Load cycles:
  • 2 Mio.
Spare parts:
Cavity seal kit:
  • material no. R961005190
Nut:
  • material no. R901241052
O-Ring for pole tube:
  • material no. R900007769
O-Ring for pole tube:
  • material no. R913014944
Electrical:
Type of voltage:
  • DC voltage
Coil type:
  • GP37 see 18325-90
RE18324-66-order(2023-11-16)
RE18324-66-02(2023-11-16)
RE18324-66-dim(2023-11-16)
  • Proportional valves direct acting spool 4-way 3-position