¹) At 80% of pressure setting
²) Only external seals for 10 valves
Note: the pressure setting must be done after installation, because the spring cannot be compressed while the cartridge is out of the cavity. For the same reason the threaded adjuster must be fully released prior to unscrewing the cartridge from the cavity.
Max. operating pressure port 1 (P):
Max. pressure admitted port 2 (T):
Fluid temperature range:
-
-30 to 100 °C (-22 to 212 °F)
Installation torque:
-
45 - 50 Nm (33 - 37 ft-lbs)
Special cavity:
-
008 (see data sheet 18325-75)
Lines bodies and standard assemblies:
-
Please refer to section “Hydraulic integrated circuit” or consult
factory
Seal kit²:
-
Code: RG0008010000100
-
material no: R930001692
Fluids:
-
Mineral-based or synthetics with lubricating properties at
viscosities of 10 to 500 mm²/s (cSt)
Recommended degree of fluid contamination:
-
Nominal value max. 10μm (NAS 8) / ISO 4406 20/18/15