Compact Directional Valves - Non-compensated and Post-compensated - Directional elements EDB Series

B8_4A... (EDB-A-VR)

Valve elements with 4 ways and 3 positions.

Control spools directly operated by solenoids with removable coils.

In the de-energized condition, the control spool is held in the central position by return springs.

Wet pin tubes for DC coils, with push rod for mechanical override; burnish surface treatment.

Single or Dual cross piloted check valves on A and B ports.

PO checks valves with 4:1 pilot ratio.

Coils can be rotated 360° around the tube.

Manual override (push-button or screw type) available as option.

Size 4

Series 00

Maximum operating pressure 250 bar (3625 psi)

Maximum flow 20 l/min (5.3 gpm)

Port connections G 3/8 SAE6 - M16x1.5

RE18300-57-order
RE18300-57-sym
RE18300-57-spool
1)
The required hydraulic symbol and spool variant can be chosen by consulting this page.
2)
For connectors ordering code see data sheet RE 18325-90.
The secondary valves have a maximum flow capacity of 6 l/min. (1.6 gpm).
RE18300-57-functional

The sandwich plate design directional valve elements B8_4A... are very compact direct operated solenoid valves which control the start, the stop and the direction of the oil flow. These elements basically consist of a stackable housing (1) with a control spool (2), two solenoids (5), and two return springs (4). The upper part of the housing is extended in order to provide space for the cavities where two PO check valves are fitted. They consist of two calibrated balls (10), with return springs (11), which allow upstream flow but lock on the respective seats (9) and prevent the return flow. The return flow is possible when they are opened by the pilot piston (8), if enough pilot pressure is present in the opposite line. When energized, the force of the solenoid (5) pushes the control spool (2) from its neutral-central position “0” to the required end position “a” or “b”, and the required flow from P to A (with B to T), or P to B (with A to T) is achieved. Once the solenoid is de-energized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool (2) returns in its neutral-central position.

Each coil is fastened to the solenoid tube by a ring nut (6). A pin (7) allows to push the spool (2) in emergency conditions, when the solenoid cannot be energized, like in case of voltage shortage.

For applications with different specifications consult us

Code
Voltage [V]
Connector type
Coil description
Marking
Coil Mat no.
OB 01
12 DC
EN 175301-803(Ex. DIN 43650)
D3601 12DC
12V DC
R901393412
OB 03
12 DC
AMP JUNIOR
D3603 12DC
12V DC
R901435507
OB 04
12 DC
AMP JUNIOR Horizontal
D3604 12DC
12V DC
R901395031
OB 07
12 DC
DEUTSCH DT 04-2P
D3607 12DC
12V DC
R901394397
OC 01
24 DC
EN 175301-803(Ex. DIN 43650)
D3601 24DC
24V DC
R901393577
OC 03
24 DC
AMP JUNIOR
D3603 24DC
24V DC
R901435494
OC 04
24 DC
AMP JUNIOR Horizontal
D3604 24DC
24V DC
R901395035
OC 07
24 DC
DEUTSCH DT 04-2P
D3607 24DC
24V DC
R901394399
OD 01
48 DC
EN 175301-803(Ex. DIN 43650)
D3601 48DC
48V DC
R901394117
OU 01
96 DC
EN 175301-803(Ex. DIN 43650)
D3601 96DC
96V DC
R901394229
AH 01
205 DC
EN 175301-803(Ex. DIN 43650)
D3601 205DC
205V DC
R901394231

For further versions (i.e. cable single lead) contact factory.

General:
Valve element with 2 solenoids:
  • 1.75 kg (3.86 lbs)
Fluid Temperature:
  • -30....+90 (-22....+194) (NBR seals)
MTTFd:
  • 150 years see RE 18350-51
Hydraulic:
Maximum pressure at P, A and B ports:
  • 250 bar (3625 psi)
Maximum pressure at T:
  • 250 bar (3625 psi)
Maximum inlet flow:
  • 20 l/min (5.3 gpm)
Hydraulic fluidGeneral properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:
  • Mineral oil based hydraulic fluids HL (DIN 51524 part 1). For use of environmentally acceptable fluids (vegetable or polyglycol base) please consult us.
Fluid Temperature:
  • -30....+100°C (-22....+212°F) (NBR seals)
Permissible degree of fluid contamination:
  • ISO 4572: βₓ≥75 X=12...15 NAS 1638: class 9
Viscosity range:
  • mm²/s 5....420
Electrical:
Voltage type:
  • DC (AC only with RAC connection)
Voltage tolerance (nominal voltage):
  • -10 .... +10%
Duty:
  • Continuous, with ambient temperature ≤ 50°C (122°F)
Coil wire temperature not to be exceeded:
  • 150°C (302°F)
Insulation class:
  • H
Compliance with:
  • Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC
Coil weight with connection EN 175301-803:
  • 0.18 kg (0.40 lbs)
Voltage:
  • 12 V
  • 24 V
  • 48 V
  • 96 V
  • 205 V
Voltage type:
  • DC
  • DC
  • DC
  • DC
  • DC
Power consumption:
  • 20 W
  • 20 W
  • 20 W
  • 20 W
  • 20 W
Current (nominal at 20 °C (68 °F)):
  • 1.62 A
  • 0.84 A
  • 0.45 A
  • 0.21 A
  • 0.01 A
Resistance (nominal at 20 °C (68 °F)):
  • 7.4 Ω
  • 28.4 Ω
  • 106.4 Ω
  • 451 Ω
  • 2062 Ω
RE18300-57-02s
Spool Variant
Curve no.
P>A
P>B
A>T
B>T
B201
2
2
1
1
E201
2
2
3
3

Measured with hydraulic fluid ISO-VG32 at 45° ±5 °C (113° ±9 °F); ambient temperature 20 °C (68 °F).

RE18300-57-perf-limits
Spool Variant
Curve no.
B201
1
E201
1

The performance curves are measured with flow going across and coming back, like P>A and B>T, with symmetrical flow areas.

In case of special circuit connections, the performance limits can change.

RE18300-57-lowest
Secondary valve setting
Curve no.
50-210 bar (700-2950 psi)
0
100-310 bar (1400-4500 psi)
1
25-50 bar (350-700 psi)
2
RE18300-57-dim
1
Solenoid tube Ø16 (0.63inch).
2
Ring nut for tube coil locking (OD 26.5); torque 3-4Nm (2.2-3 ft-lb).
3
Identical label.
4
Clearance needed for connector removal.
5
Optional push-button manual override, EP type, for spool opening: it is pressure stuck to the ring nut for tube coil locking.Mat no. R930059524.
6
Optional screw type manual override, EF type, for spool opening: it is screwed (torque 5-6Nm (3.7-4.4 ft-lb)) to the tube as replacement of the coil ring nut. Mat no. R930059561.
7
Flange specifications for coupling to ED intermediate elements.
8
For tie rod and tightening torque information see data sheet RE 18301-90.
9
O-Ring for T and P line on ED flange.
10
Space needed for secondary valve in configuration 1.
11
A and B ports
RE18300-57-elec-conn