Compact Directional Valves - Non-compensated and Post-compensated - Directional elements EDB Series

EDBZ-VEI

Valve elements with 4 ways and 2 positions.

Control spools directly operated by solenoids with removable coils.

In the de-energized condition, the control spool is held in the central position by return spring.

Wet pin tubes for DC coils, with push rod for mechanical override; burnish surface treatment.

Manual override (push-button or screw type) available as option.

Additional solenoid cartridge 2/2, NO or NC, single locking or dual locking on port A.

Size 4

Series 00

Maximum operating pressure 310 bar (4500 psi)

Maximum flow 25 l/min (6.6 gpm)

Port connections G 3/8 SAE6 - M16×1.5

1) For connectors ordering code see data sheet RE 18325-90.

2) VEI solenoid cartridge must be ordered separately.

The secondary valves have a maximum flow capacity of 6 l/min. (1.6 gpm).

RE18300-54-order
RE18300-54-sym
RE18300-54-spool
RE18300-54-functional

The sandwich plate design directional valve elements B8_58… are very compact direct operated solenoid valves which control the start, the direction and the leak free stop of the oil flow. These elements basically consist of a stackable housing (1) with a control spool (2), one solenoid (5), a spring holder plug (7); two return springs (4); a solenoid screw-in cartridge VEI (8) with its coil (9). When energized, the force of the solenoid (5) pushes the control spool (2) from its rest position “0” to the end position “b”. If there is a solenoid cartridge VEI (8) type C, A, O, the oil flow goes directly to the port A; if there is a solenoid cartridge VEI (8) type D (Dual locking), it is necessary to energize the solenoid cartridge as well in order to allow the oil flow to the port A. Once the solenoid (5) is de-energized, the return spring (4) pushes the spool thrust washer (3) back against the housing and the spool (2) returns in its rest position. The leak free holding at port A is provided by energizing (or de-energizing, if the VEI is NC type) the solenoid cartridge. By energizing open the VEI (8) (“C“ and “A“ versions), the A port is open to tank and downstream flow is possible. The coils are fastened to the respective solenoids (5) and VEI (8) by the ring nuts (6) and (10).

Code
Voltage [V]
Connector type
Coil description
Marking
Coil Mat no.
=OB 01
12 DC
EN 175301-803(Ex. DIN 43650)
C3601 12DC
12 DC
R933000044
=OB 03
12 DC
AMP JUNIOR
C3603 12DC
12 DC
R933000047
=OB 07
12 DC
DEUTSCH DT 04-2P
C3607 12DC
12 DC
R933000048
=OC 01
24 DC
EN 175301-803(Ex. DIN 43650)
C3601 24DC
24 DC
R933000053
=OC 03
24 DC
AMP JUNIOR
C3603 24DC
24 DC
R933000057
=OC 07
24 DC
DEUTSCH DT 04-2P
C3607 24DC
24 DC
R933000058
=OV 01
24 RAC
EN 175301-803(Ex. DIN 43650)
C3601 21.5DC
21.5 DC
R933000054
=OW 01
110 RAC
EN 175301-803(Ex. DIN 43650)
C3601 98DC
98 DC
R933000060
=OZ 01
230 RAC
EN 175301-803(Ex. DIN 43650)
C3601 207DC
207 DC
R933000062
General:
Valve element with solenoid:
  • 1.8 kg (3.96 lbs)
Fluid Temperature:
  • –20....+50 (-4. +122) (NBR seals)
Hydraulic:
Maximum pressure at P, and A ports:
  • 310 bar (4500 psi)
Maximum pressure at T:
  • 250 bar (3625 psi)
Maximum inlet flow:
  • 25 l/min (6.6 gpm)
Hydraulic fluid General properties: it must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example:
  • Mineral oil based hydraulic fluids HL (DIN 51524 part 1). Mineral oil based hydraulic fluids HLP (DIN 51524 part 2). For use of environmentally acceptable fluids (vegetable or polyglycol base) please consult us.
Fluid Temperature:
  • –20....+80 °C (-4. +176°F) (NBR seals)
Permissible degree of fluid contamination:
  • ISO 4572: βₓ≥75 X=12...15
  • ISO 4406: class 20/18/15
  • NAS 1638: class 9
Viscosity range:
  • 5....420 mm²/s
Electrical:
Voltage type:
  • DC (AC only with RAC connection)
Voltage tolerance (nominal voltage):
  • -10 .... +10%
Duty:
  • Continuous, with ambient temperature ≤ 50°C (122°F)
Coil wire temperature not to be exceeded:
  • 150 °C (302°F)
Insulation class:
  • H
Compliance with:
  • Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC
Coil weight with connection EN 175301-803:
  • 0.215 kg (0.44 lbs)
Voltage:
  • 12 V
  • 24 V
  • 24 V +RAC (21,5)
  • 110 V +RAC (98)
  • 230 V +RAC (207)
Voltage type:
  • DC
  • DC
  • DC
  • DC
  • DC
Power consumption:
  • 26 W
  • 26 W
  • 29 W
  • 29 W
  • 29 W
Current (nominal at 20 °C (68 °F)):
  • 2.15 A
  • 1.10 A
  • 1.20 A
  • 0.29 A
  • 0.14 A
Resistance (nominal at 20 °C (68 °F)):
  • Note: For applications with different specifications consult us
  • 5.5 Ω
  • 22 Ω
  • 18 Ω
  • 338 Ω
  • 1430 Ω
RE18300-54-02
Spool Variant
Curve no.
 
B>T
P>A
X301
1
2

Measured with hydraulic fluid ISO-VG32 at 45° ±5 °C (113° ±9 °F); ambient temperature 20 °C (68 °F).

RE18300-54-performance-limit
Spool Varian
Curve no.
X401
1

The performance curves are measured with flow going across and coming back, like P>A and B>T, with symmetrical flow areas.

In case of special circuit connections, the performance limits can change.

RE18300-54-minimum-flow
RE18300-54-lowest-pressure
Secondary valve setting
Curve no.
50-210 bar (700-2950 psi)
0
100-310 bar (1400-4500 psi)
1
25-50 bar (350-700 psi)
2
RE18300-54-dim
1
Solenoid tube Ø 14 mm (0.55 inch).
2
Screw-in solenoid cartridge VEI hex 24 mm (0.94 inch). Torque 39-51Nm (28.8-37.6 lb-ft).
3
Ring nut for coil locking (OD 20.5 mm); torque 3-4Nm (2.2-3 ft-lb).
4
Identification label.
5
Clearance needed for connector removal.
6
Optional push-button manual override, EP type, for spool opening: it is pressure stuck to the ring nut for coil locking.
Mat no. R933000042.
7
Optional screw type manual overide, EF type, for spool opening: it is screwed (torque 6-7 (4.4-5.2 ft-lb)) to the tube as replacement of the coil ring nut. Mat no. R933006377.
8
Optional manual override for VEI cartridge: it can be push/pull or screw type. Please refer to the VEI catalogue for details.
9
Flange specifications for coupling to ED intermediate elements.
10
For tie rod and tightening torque information see data sheet RE 18301-90.
11
O-Rings for P and T ports.
12
Space needed for secondary valve in configuration 1.
13
A and B ports.