Manual Override Options for Hydraulic Cartridge Valves
Note: All manual override features are intended for emergency use, not for continuous-duty operation.
Manual Override "M" Option for Two-Position Pull-Type Solenoid Valves
Manual Override "M" and "B" Option for Three-Position Push/Pull-Type Solenoid Valves
Operation of Manual Override: To override, push the knurled button to activate the coil #2 (S2) function, or pull the knob
to activate the coil #1 (S1) function.
![MO_M&B_3-pos.gif](/contentassets/7e07f32fe37440639b128bdfb2a4f347/mo_mb_3-pos.gif)
Manual Override "K" Option for Three-Position Push/Pull-Type Solenoid Valves, Detented
Operation of Manual Override: To override, from neutral push button in, twist clockwise 90°, to activate coil #2 (S2) function.
From neutral pull and twist 90° counterclockwise to activate coil #1 (S1) function.
![MO_K.gif](/contentassets/7e07f32fe37440639b128bdfb2a4f347/mo_k.gif)
Manual Override "M" and "B" Option for Three-Position HyPerformance™ Solenoid Valves, Detented
Operation of Manual Override: To override, from neutral push knob down slightly, rotate 90° counterclockwise and pull to activate
coil #1(S1) function. Rotate an additional 90° counterclockwise to engage detent.
From neutral push down knob completely to activate coil #2 (S2) function. Rotate 90° clockwise to engage detent.
![MO_M&B_3-pos-HyPerf.gif](/contentassets/7e07f32fe37440639b128bdfb2a4f347/mo_mb_3-pos-hyperf.gif)
Manual Override "T" Option for HPV Electro-Proportional Valves
Sizes: -20, -21, -30, -31 (for -12 cavities)
Operation of Manual Override: Rotate knob counterclockwise to activate override function.
![MO_T.gif](/contentassets/7e07f32fe37440639b128bdfb2a4f347/mo_t.gif)
Manual Override "J" and "Y" Options for Pull-Type Solenoid Valves
Sizes: -08, -38, -10, -12, -16
Operation of Manual Override: Pull and hold to override.
![MO_JandY.gif](/contentassets/7e07f32fe37440639b128bdfb2a4f347/mo_jandy.gif)
Manual Override "M" and "G" Options for PV and ZL Proportional Valves
Operation of Manual Override: Rotate knob counterclockwise to activate override function.
![MO_MandG.gif](/contentassets/7e07f32fe37440639b128bdfb2a4f347/mo_mandg.gif)
Manual Override "P" and "K" Options for Two-Position Push-Type Solenoid Valves
Operation of Manual Override: Push and hold to override.