Cartridge Valves - Electro-proportional Valves - Flow Controls - Pressure Compensated - Restrictive Type - Poppet Type - Normally Closed

HSPEC12-34

SOLENOID PROPORTIONAL FLOW CONTROL VALVE POPPET, NORMALLY CLOSED, PRESSURE COMPENSATED

Overview

Description

The hspec12-34xx is a high pressure, proportional solenoid-operated, poppet type, restrictive type, pressure compensated, normally closed flow control, screw-in hydraulic cartridge valve with built-in damping and load holding features.

Operation

With inlet at port 3 the valve will regulate flow out of port 2 regardless of load pressure with flow rate proportional to current applied to the solenoid. Port 1 must be connected to port 3 to provide load sense function for the compensator. When de-energized, the valve blocks flow from port 3 to port 2 while allowing free flow in opposite direction.

Features

  • Industry-common cavity.
  • Continuous-duty rated coils.
  • Reduced manifold space claim.
  • Efficient wet-armature construction.
  • Optional waterproof E-Coils rated up to IP69K.
  • Patented high-strength solenoid tube
  • All HyPerformance™ valves are tested to the rigorous standards of NFPA specification T2.6.1 and are tested at a verification level of 90% and an assurance of 99%
Pressure Ratings
Pressure rating:
  • 350 bar (5075 psi)
  • 420 bar (6090 psi) 10% cycle life
Proof pressure:
  • 690 bar (10000 psi)
Burst pressure:
  • 1380 bar (20000 psi)
Flow Ratings
Flow rating:
  • 60 lpm (16.0 gpm) Standard metering
  • 64 lpm (17.0 gpm) Linear metering
Maximum internal leakage:
  • 8 drops/min Port 3 to 2 with at port 3 350 bar (5075 psi)
Hysteresis flow:
  • lpm (gpm) Maximum
Temperature Ratings
Operating fluid temperature:
  • -40 to 100 °C (-40 to 212 °F) With buna N seals
  • -26 to 204 °C (-15 to 400 °F) With fluorocarbon seals
  • -54 to 107 °C (-65 to 225 °F) With urethane seals
Storage temperature:
  • -40 to 70 °C (-40 to 160 °F)
Ambient temperature:
  • -40 to 70 °C (-40 to 160 °F)
Fluids:
  • Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range:
  • 7.4 to 420 cSt
Maximum operating contamination level:
  • 18/16/13 per ISO 4406
Unit weight:
  • 0.32 kg (0.70 lb) Without coil and nut HSPEC12-34 HSPEC12-34A
  • 0.33 kg (0.72 lb) HSPEC12-34T hspec12-34at
Internal wetted surface area:
  • 313.4 cm² (48.57 in²) HSPEC12-34, HSPEC12-34A
  • 317.8 cm² (49.26 in²) Hspec12-34t, hspec12-34at
Note:
  • With size 10 e-series coil
Maximum control current:
  • 1300 mA Coil 12 V
  • 650 mA Coil 24 V
Threshhold current:
  • 200 to 550 mA Coil 12 V
  • 100 to 275 mA Coil 24 V
Dither PWM frequency:
  • 100 to 200 Hz
HSPEC12-34_Perf_Chrt1(2022-02-24) HSPEC12-34_Perf_Chrt2(2022-02-24)
HSPEC12-34_Dim_Dwg(2022-02-24)
Cavity:
Cartridge installation torque:
  • 156 to 170 N-m (115 to 125 ft-lb) Steel/ductile iron cavity
  • 122 to 136 N-m (90 to 100 ft-lb) Aluminum cavity
Coil nut torque:
  • 7 to 10 N-m (5 to 7 ft-lb)
Orientation restriction:
  • None
Seal kit:
  • Hsk12-3n-tb Buna N
  • SK12-3V-TB Fluorocarbon
  • SK12-3U-OO Urethane
HSPEC12-34_Order(2022-02-24)

Model Options

HSPEC12-34DE-H-J-L
D Poppet Metering
CODE
DESCRIPTION
A
Linear Poppet Metering
BLANK
Standard Poppet Metering
E Manual Override
CODE
DESCRIPTION
BLANK
NONE
T
Variable Position Override, Red Knurled Knob
H Line Body
CODE
DESCRIPTION
0
No Body
12HT
Ductile Iron SAE 12
J Seal
CODE
DESCRIPTION
N
Buna-N
V
Fluorocarbon
U
PPDI Urethane
L Coil
CODE
DESCRIPTION
0
No Coil
10EL
10 VDC, E-Coil, Dual Lead Wires
10ER
10 VDC, E-Coil, Deutsch
12EG
12 VDC, E-Coil, DIN 43650
12EJ
12 VDC, E-Coil, AMP Jr.
12EL
12 VDC, E-Coil, Dual Lead Wires, 18 inches long
12EL/36
12 VDC, E-Coil, Dual Lead Wires, 36 inches long
12ER
12 VDC, E-Coil, Deutsch
12EY
12 VDC, E-Coil, Metri-Pack 150
20ER
20 VDC, E-Coil, Deutsch
24EG
24 VDC, E-Coil, DIN 43650
24EJ
24 VDC, E-Coil, AMP Jr.
24EL
24 VDC, E-Coil, Dual Lead Wires, 18 inches long
24EL/36
24 VDC, E-Coil, Dual Lead Wires, 36 inches long
24ER
24 VDC, E-Coil, Deutsch
24EY
24 VDC, E-Coil, Metri-Pack 150