Cartridge Valves - Flow Control Valves - Flow divider

DSDN-16A

RE18321-23-01(2023-11-07)
Description

Input flow at 3 will be divided and output equally to 2 and 4 independent of system pressures. Should either 2 or 4 become blocked in flow division mode, approximately 5% of the input flow will be transmitted to the open port. Flow combining is not permitted.

Slippage (tolerance) from theoretical divided flows: ±5% to ±10%, depending from inlet flow (see diagram). N.B. Slippage is lowest toward upper limit of nominal range.

General:
Pressure min. - max.:
  • 10 - 350 bar (145 - 5000 psi)
Flow range:
  • see “Range of total flow” table
Fluid temperature range:
  • -30 to 100 °C (-22 to 212 °F)
Installation torque:
  • 108 - 122 Nm (80 - 90 ft-lbs)
Division ratio:
  • 50% - 50%
Weight:
  • 0.41 kg (0.9 lbs)
Cavity:
  • CA-16A-4N (see data sheet 18325-70)
Lines bodies and standard assemblies:
  • Please refer to section “Hydraulic integrated circuit” or consult factory
Seal kit1):
  • Code: RG16A4010530100
  • material no: R930000973
Fluids:
  • Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm2/s (cSt)
Recommended degree of fluid contamination:
  • Nominal value max. 10µm (NAS 8) / ISO 4406 19/17/14
Installation:
  • No restrictions
Other Technical Data:
  • See data sheet 18350-50
RE18321-23-02(2023-11-07)
RE18321-23-order(2023-11-07)