Cartridge Valves - Pressure Control Valves - Pressure Reducing and Relieving

VRPR-10A

RE18318-53-01(2023-11-23)
Description

Initially, flow passes freely from 2 to 1. When the pressure at 1 exceeds the pressure setting, the valve acts to restrict input flow at 2. This increases the pressure drop through the valve and maintains consistent pressure at 1. The spring chamber is drained at 3 to prevent a build-up of back-pressure against the spool. Additionally, if pressure at 1 rises above the pressure setting, flow is relieved to 3 until the setting is re-attained.

¹) 1 - 3 to 80% of pressure setting

²) Standard version X=03 type

³) Only external seals for 10 valves

General
Max. operating pressure port 2 (P):
  • 350 bar (5000 psi) 210 bar (3000 psi) for version Z=01
Max. pressure admitted port 1 (A):
  • 105 bar (1500 psi)
Max. flow:
  • 30 l/min (8 gpm)
Max. internal leakage¹):
  • 50 cm³/min. (3 cu.in./min.)
Fluid temperature range:
  • -30 to 100 °C (-22 to 212 °F)
Installation torque:
  • 41 - 47 Nm (30 - 35 ft-lbs)
Weight²):
  • 0.26 kg (0.57 lbs)
Cavity:
  • CA-10A-3N (see data sheet 18325-70)
Lines bodies and standard assemblies:
  • Please refer to section “Hydraulic integrated circuit” or consult factory
MTTFd:
  • 150 years see data sheet 18350-51
Seal kit³):
  • Code: RG10A3010520100
  • material no: R901111369
Fluids:
  • Mineral-based or synthetics with lubricating properties at viscosities of 10 to 500 mm²/s (cSt)
Recommended degree of fluid contamination:
  • Nominal value max. 10μm (NAS 8) / ISO 4406 19/17/14
Installation position:
  • No restrictions
Other Technical Data:
  • See data sheet 18350-50
RE18318-53-02(2023-11-23)
RE18318-53-order(2023-11-23)
RE18318-53-dim(2023-11-23)