General:
Weight:
  • 0.60 kg (1.3 lbs)
Installation position:
  • Any
Fluid Temperature:
  • -20 to 120 (-4 to 248)
Salt spray test to DIN 50021:
  • 720 h
Hydraulic:
Max. operating pressure port 1, 2:
  • 350 bar (5075 psi)
Maximum Δp:
  • 350 bar (5075 psi) (250 bar (3625 psi) for optimal metering and flow capacity)
Nominal flow:
  • 85 l/min. at 14 bar Δp (22 gpm at 200 psi Δp)
Hysteresis Less than 7% up to 90% of I-MAX.:
Less than 10% above 90% of I-MAX.:
Recommended dither frequency (PWM) 100 Hz:
Max. internal leakage:
  • 10 drops/min. (at Δp=150 bar; HLP46, Toil = 40°C)
Fluid temperature range:
  • -20 to 80 °C (-4 to 176 °F)
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of 15 to 380 mm2/s (cSt):
Recommended degree of fluid contamination:
  • (NAS 8) / ISO 4406 19/17/14
MTTFD:
  • 150 years see RE 18350-51
Cavity:
  • CA-12A-2N see 18325-70
Load cycles:
  • 2 Mio.
Spare parts:
Cavity seal kit:
  • material no. R961011031
Coil nut:
  • material no. R901440340
Spacer ring:
  • material no. R901168656
Electrical:
Type of voltage:
  • DC voltage
Coil type:
  • GP37 see 18325-90
RE18323-74-order(2023-11-08)
RE18323-74-02(2023-11-08)
RE18323-74-dim(2023-11-08)
  • Proportional valves pilot operated poppet type 2-way flow regulator not compensated