The FD52-45 is a screw-in cartridge, spool type flow divider/combiner valve

Operation

The cartridge valve pressure compensated proportional division of inlet flow or combining of two return flows regardless of system operating pressure conditions. The valve provides synchronizing flow in dividing and combining modes

Features

  • Hardened parts for long life.
  • Quiet, modulated response.
  • Wide operating flow range.
  • Synchronizing in dividing and combining modes.
  • Floating cage — high installation torque.
  • Industry-common cavity.

Ratings

Pressure Ratings
Pressure rating
345 bar (5000 psi)
420 bar (6090 psi) 10% duty cycle
Pressure drop
20.5 bar (300 psi) At maximum inlet flow
Flow Ratings
Inlet flow rating
15 to 60 lpm (4.0 to 16.0 gpm) Model code 44
23 to 90 lpm (6.0 to 24.0 gpm) Model code 66
30 to 106 lpm (8.0 to 28.0 gpm) Model code 88
Synchronizing flow
Approximately 10% of maximum inlet flow
Flow accuracy
10 % Of inlet flow for -44 and -66 models
15 % Of inlet flow for -88 models
Temperature Ratings
Maximum operating fluid temperature
-40 to 100 °C (-40 to 212 °F) With buna N seals
-26 to 204 °C (-15 to 400 °F) With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F) With polyurethane seals
Storage temperature
-40 to 70 °C (-40 to 160 °F)
Ambient temperature
-40 to 90 °C (-40 to 194 °F)
Other Ratings
Corrosion protection
960 hr salt spray per ASTM b117 (model number - gfd52-45)

Operating Parameters

Fluids
Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range
7.4 to 420 cSt
Maximum operating contamination level
18/16/13 per ISO 4406

Properties

Cartridge weight
0.24 kg (0.53 lb)
Internal wetted surface area
238 cm² (43.8 in²)

Performance

FD52-45_Flow-Pressure

Dimensions

FD52-45_Dim

Materials

Materials

Cartridge: Weight: 0.24 kg (0.53 lb); Steel with hardened work surfaces. Zinc-plated exposed surfaces; Buna N O-rings and polyester elastomer back-ups standard.

Ported Body: Ductile iron body required for operation over 207 bar (3000 psi). Aluminum bodies are available for lower pressure operation. FD-type bodies recommended but a standard 4-way body may also be used with Port 1 plugged.

Installation Specifications

Cavity
VC12-4
HVC12-4 for applications with pressure excursions up to 420 bar (6090 psi)
Cartridge installation torque
99 to 104 N-m (73 to 77 ft-lb)
156 to 169 N-m (115 to 125 ft-lb) For applications with pressure excursions up to applications with pressure excursions up to 6090 psi [420 bar]
Orientation restriction
None

Accessories

Seal kit
SK12-4X-MMM (x=seal option) X=seal option

Order code

POSITION
CODE
DESCRIPTION
FD52-45-H-J-N
H
Line Body
H
0
No Body
H
10T
Aluminum SAE 10
H
12T
Aluminum SAE 12
H
12TD
Ductile Iron SAE 12
J
Seal
J
N
Buna-N
J
V
Fluorocarbon
J
P
Polyurethane
N
Flow Dividing/Combining
N
22
Not listed in outline
N
33
Not listed in outline
N
44
50/50 Rated at 15.0-60.0 lpm (6.0-24.0 gpm)
N
55
Not listed in outline
N
66
50/50 Rated at 23.0-90.0 lpm (6.0-24.0 gpm)
N
88
50/50 Rated at 30.0-106.0 lpm (8.0-28.0 gpm)
FD52-45_Order